Programming Manual EURO
RINS1291-3 Page: 57
4.23.2 Programming Contact iD, SIA, SMS, WebWayOne and Chiron
The Contact iD, SIA and SMS signalling protocol can also be used. However the programming
differs from Fast Format, here you have to select the content types you would like to be sent
to the Alarm Receiving Centre. The table below shows the types you may have.
Content Types
1 Set: System Set, Secure set system, System rearm, System Final Set,
2 Unset: System Unset, System unset by Autoset, Autoset cancelled by a user, Forced Set, set
by Autoset
3 Special Unset: Special Unset, Access Exit Requested
4 Set Fail: Set Failure, Set Failure with input
5 Alarms: Case/SAB Tamper, Power Fault, Fire Input Active, Day Alarm Input Active, Intruder
Input Active, Radio Low Battery, Fire Key Pressed, Burglary Alarm, Gas Alarm, Tamper Alarm,
CCTV, Tamper on Input, Entry/Exit Alarm, No Input Activity Sent, Day Alarm, Perimeter,
Interior Alarm
6 First Alarm: Burglary Alarm Once, Gas Alarm Once, Tamper Alarm Once, Entry/Exit Alarm
Once, Day Alarm Once, Interior Alarm Once,
7 Alarm Silenced
8 Confirmed: Confirmed Signal
9 Lo Tech Faults: STU Telecom Line OK, CCTV Line Fail, CCTV Line OK, Telecom Line OK,
10 High Tech Faults: Any faults from Mains, Battery, Communications, Fuses, Device
Fail/Restored, Digi Fail Comms, STU Comms Failure, Detector Fault, Detector Masked, Telecom
Line Fault,
11 System Changes/Resets: Clock Set From/To, Added/Deleted/Changed Code, System Restart,
Twin Device, Excess Current, Logs Cleared, Engineer Reset, Clean Start, Site Changed, CHC Call
Failed, Logs nearly full, PC Clock Set to,
12 Manager Info: Unset System
13 Engineer Info: Engineer Access/Exit
14 Access Control Alarm: Door Left Open/Forced
15 Access Control Info: Tag at Reader
16 Access Control Ref: Invalid Tag
17 Special Log Switcher On: Input Special Log Switcher Open
18 Special Log Switcher Off: Input Special Log Switcher Closed
19 Special Log Other On: Input Special Log Open
20 Special Log Other Off: Input Special Log Close
21 Shunt/Ward Set: Shunt Opened Ward Set
22 Shunt/Ward Unset: Shunt Closed Ward Unset/Silenced
23 Shunt/Ward Alarm: Ward Alarm
24 Walk Test: Input Walk Tested
25 Restores: Burglary Restore, Gas Restore, Tamper Restore, Entry/Exit Restore, Tamper on
Input Restore, 2 Key PA Restore, iD line short restore, Fuse fail restore, Case Tamper Restore,
SAB Tamper Restore, Day Alarm Restore, Interior Alarm Restore, Radio Low Battery Restore,
Radio Jamming Restore, Radio Supervision Restore
26 Not Used
27 Mains Fail: Mains Fail Alarm/Restore
28 Duress: Fire Alarm, PA Alarm, HoldUp Alarm, Duress Code, Fire Alarm Once, PA Alarm Once,
Holdup Alarm Once, Fire Restore, PA Restore, Hold Up Restore,
29 Emergency: Emergency Input Opened, Emergency Alarm Once, Emergency Restore,
30 Input Status: Input Omitted, Input Force Armed
31 Aborts: Stopped Set, Abort
4.23.3 PABX Systems (Only relevant to SMS)
Please note for PABX telephone systems (where a “9” is needed in order to dial an outside
line), you must put “NN” before the account number in the “account reference” part of the
programming (see below). If you haven’t been given an account number then the account
reference “NN1111” would be OK to use. This needs to be entered on the keypad.
*Not available on the EURO 28