4.19.3 Fault Codes
Fault codes shown in the system log include numeric code to identify the equipment at which
the fault is present. For example:
Device Failure 203
Mains Failure 400
The first digit identifies the type of device:
1 = Control Panel
2 = Keypad
3 = Tag Reader or External Proximity Reader
4 = Zone Expander Module (ZEM)
5 = Output Module
The remaining digits identify the address of the device, so if the display showed “Device Failure
203”, then there would be a possible wiring fault on the keypad that is addressed as “03”. If
the display showed “Mains Failure 400”, then the power supply fitted to the ZEM addressed as
“00” needs to be checked.
Please note a list of all the fault codes and log meanings are shown on page: 62.
Review Logs
Using the and keys, scroll to
‘REVIEW LOGS?
Press the key
Panel Log
Press the key to view the panel log.
You will be returned to the Engineer Menu.
The log will be displayed. Use the and
keys to scroll through the log.
For more information on an event (such
as alarm silenced for example) press the
key.
When you wish to exit, press the key.
Access Log*
Repeat the above for the Access log. When
you wish to exit, press the key. You will
be returned to the Engineer Menu.
*Not available on the EURO 28