4.8 System Displays
Please see page 9, “Text Programming” section for this function as it requires programming
Area text, sign on messages etc.
4.8.1 Area Texts
You may choose how you want each Area/Level Set to be displayed, i.e. “Area A” may be used
to fully Set a house therefore you may want to call it “Full House Set” for example. You can
have a maximum of 16 characters on the display.
4.8.2 Sign On Message
The Sign on Message is the main display on the top line in unset mode.
4.8.3 Site Name
The Site Name is used as a “Site Reference” which if used must be also used within the EURO
Insite Software in order for the software to connect to the EURO system.
4.8.4 Display When Set / Display Alarms / Display HU’s
If ‘Display when set’ is enabled, then the Area Text will be displayed on the LCD keypad once
the system is fully set. The Default is No. (Not compliant with PD6662 / EN50131-1)
If Display Alarms / HU’s are enabled, they will show any alarms that are activated before a
valid user code/tag is entered. If Display Inputs is enabled, any inputs activated in day mode
will be displayed. Not available on EURO 28.
System Displays
Using the and keys, scroll to
‘SYSTEM DISPLAYS?’
Press the key
Area Text
Enter the desired text for the Area; press the
key to enter the text for all other Areas.
You can also add/change the text for “Full”
Area Setting, the sign on message and the
site name label.
Press the key once you have changed
each text display.
Display When Set*
Enter : for No
Enter : for Yes
Press the key. You will be returned to
the Engineer Menu. *This is not available