4.15 Change Outputs
Any output type may be programmed to any of the systems outputs. Outputs must be used
within their rated capacity. Please see the installation manual.
NOTE: Only the ATE outputs can be inverted.
4.15.1 Output Types
Type Active Restore
0000 Not Used (permanently off)
0001 Fire At alarm
When a valid code is
entered
0002 Hold Up Any
At a HU or Duress alarm
(This includes keypad HU)
When a valid code is
entered
0003 Intruder Any
At alarm, while system is
disarmed
At first valid code entry
and at end of confirm time.
0004 Final Set All* When system is FULLY armed At code entry to unset
0005
Misoperation Any
(Abort)
When system is silenced after
any ‘intruder’ output is
triggered
After 2 minutes
0006 Confirmed Any
When further input active in
any area after ‘intruder’
alarm
At next code entry
0007 Tamper Any Any tamper alarm
At code entry to silence
And at end of confirm time.
0008 Duress
At a Duress alarm (i.e. from a
keypad)
When a valid code is
entered
0009 HU Device Any At alarm on a HU input only
When a valid code is
entered
0010 Gas* At alarm
When a valid code is
entered
0011 Set Fail
Pre-set time after start of exit
time, if exit procedure is not
complete
At code entry to rearm
0012 Entry Deviation
When deviation from entry
route occurs, during entry
time
At code entry to unset
0013 Secure Intruder Any
At alarm, after exit time
started, until unset
At first valid code entry
and at end of confirm time.
0014 Siren Any When alarm live
When alarm silenced or
when siren timer expires
0016 Strobe Any When alarm live
When alarm silenced or
when strobe timer expires
0017 Omit Rearm Any
Input omitted if active (or in
alarm condition) at the end of
confirmation time.
When system disarmed
0018 Unconfirmed Any Any intruder or Tamper alarm At code entry to silence
0019 Can Set All*
If all inputs and technical
faults in system are clear.
Also once entry time has
started
If fault exists, and after
final set
0020 Exit Starts All*
At start of exit time to set
LAST area
At code entry to unset
FIRST area (i.e. no longer
fully set)
0021 Exit Starts Any
When exit time starts to set At code entry to unset