Programming Manual EURO
RINS1291-3 Page: 37
Type Active Restore
test call is sent.(only used for
specific GSMs)
0064
Test ATS
For use with ATE
complying with BSIA
Form 175 to initiate
test call to ARC by each
available path.
Test signalling through PSTN
and GSM. Activates when a
test call is sent.
When test completed
0065 Zone Activity Fail
If an input with NAT timer
active does not trigger in the
defined period
Next valid code entry
0066 ATE not used
Makes the ATE pin 5V or 0V depending if ATE outputs are
inverted
A repeating block of output types should be noted:
0202 Hold Up A As 0002 for Area A / Level set A events only
0203 Intruder A As 0003 for Area A / Level set A events only
0204 Final Set A As 0004 for Area A / Level set A events only
0206 Confirmed A As 0006 for Area A / Level set A events only
0207 Tamper A As 0007 for Area A / Level set A events only
0208 Duress A As 0008 for Area A / Level set A events only
0209 HU Device A As 0009 for Area A / Level set A events only
0210 Fire Reset A* As 0010 for Area A / Level set A events only
0213 Secure Intruder A As 0013 for Area A / Level set A events only
0214 Siren A As 0014 for Area A / Level set A events only
0216 Strobe A As 0016 for Area A / Level set A events only
0217 Omit At Rearm A As 0017 for Area A / Level set A events only
0218 Unconfirmed A As 0018 for Area A / Level set A events only
0219 Can Set A As 0019 for Area A / Level set A events only
0220 Exit Starts A As 0020 for Area A / Level set A events only
Then this pattern repeats for each other area, so that:
0221-0240 Area / Level set B 0361-0380 Area / Level set 4**
0241-0260 Area / Level set C 0381-0400 Area / Level set 5**
0261-0280 Area / Level set D 0401-0420 Area / Level set 6**
0281-0300 Area / Level set 0* 0421-0440 Area / Level set 7**
0301-0320 Area / Level set 1* 0441-0460 Area / Level set 8**
0321-0340 Area / Level set 2* 0461-0480 Area / Level set 9**
0341-0360 Area / Level set 3*
1xxx Follow input xxx
When input is
activated
When input clears
i.e. add 1000 to the input number to select output required
Area Sounder
At output 2 of the TMZ (fixed as
loudspeaker)
*Not available on the EURO 28
At Default
Output 1: Not Used
Output 2: Not Used
Output 3: Strobe Any (0016)
Output 4: Siren Any (0014)
Kommentare zu diesen Handbüchern