EURO Programming Manual
Page: 36 RINS1291-3
Type Active Restore
FIRST area LAST area
0022 Final Set Any When FIRST area is set
At code entry to unset
LAST area
0023 Strobe Set Fail
Works similar to output 016, but also fires if the set fail
timer expires.
0025 Keyswitch unset
This output turns on for 5 seconds when the system is
disarmed via a keyswitch input (either pulsed or latched
keyswitch)
0026 Set with Omit Activates when inputs are omitted on setting
0031 Entry* Live during any exit time
0032 Exit* Live during any entry time
0033 Entry/Exit Live during any entry or exit time
0034 Lights
When exit or entry timer
starts
20 seconds after set/unset
procedure completed
0035
Follow Input*
See page: 39.
When input triggers
Dependant upon
programming
0036 Shunt Fault* See Shunt Inputs - Page: 19
0037
Reset 1 (Viper
Reset)
At code entry to set After 3 seconds
At code entry to set When unset
0038
Reset 2 (Viper
Set/Unset)
Re-triggers whenever an additional area is set
0039 PIR Latch 1 When set (and in Walk Test) At alarm, or when unset
0040 PIR Latch 2 This is the inverse polarity to PIR Latch 1
0041 Mains Good Output showing the mains is healthy
0042 Detr Indn Enable*
This output activates during walk test and also when a
code is entered to view indications – staying activated for
the time for which the indications are viewed.
0043 Follow Test New output for alternative bell test by activating SAB
0044 Off During Test New output for alternative bell test by activating SAB
0048 Detr Walk Test
This output is active during walk test, and will only
deactivate when all detectors have been tested.
0051 Line Fault
When Line Fault signalled by
communicator
When fault clears
0052 Mains Fail
After pre-set time without
mains power
On restoration of mains
0053 Battery Faults
When battery disconnected or
load fail detected
At next valid code entry
0054 Low Volts At fault When fault clears
0055
Global Fault 1
(Faults: Modem,
Battery, Fuse, Line,
Mains)
Activates if fault occurs only
when system is armed
When all faults cleared
0056
Global Fault 2
(Faults: Modem,
Battery, Fuse, Line,
Mains)
Activates if fault occurs at
any time
When all faults cleared
0057 German Relay* DO NOT USE
0058 Guard Code Used When ‘guard’ code accepted After 60 seconds
0059 Engineer Access When entering Engineer Mode
When leaving Engineer
Mode
0060 Initialise Digi At power up Live for 45 seconds only
0063 Test ATE/GSM*
Test signalling through PSTN
and GSM. Activates when a
When test completed