CASTLE EURO Installationshandbuch Seite 42

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 68
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 41
EURO Programming Manual
Page: 42 RINS1291-3
4.17 Site Options
A full range of site options is available to tailor the operation of the system.
4.17.1 Site Option Types
Option Default
Function
Set With Fault Yes
If ‘YES’: Allows setting with the following faults active: Device
fail, Mains fail, Battery faults, Fuse faults, SMS failure, relay
sirens 1&2, relay Strobe faults.
Set With
Tamper+
No
If ‘YES’: Allows setting with the following faults active: Case
tamper and System tampers.
Set With ATS
Fault
Yes
If ‘YES’: Allows setting with the following faults active: Telecom
line fail, Modem failed, STU/ATE line fault, STU/ATE one path fail,
Digi dial fail, STU/ATE comms fail.
Set With
Ward TFault*
Yes
If ‘YES’: Allows a ward to be set if mains, battery, telecom line,
or other system fault is present.
Set Fail =
Alarm
No
If ‘YES’ = A graduated alarm will be generated when ‘Set Fail’
timer expires (see Change Timers), if exit procedure is still
incomplete. Set fail output will trigger.
If ‘NO’ = Exit time will continue until the Exit route is clear.
Do Bat Load
Test
No
If ‘YES’: Programmes the system to perform a full load test of
the battery at 7.00am each day.
Ward
Misoperation*
No
If ‘YES’ Allows a Misoperation (Abort) signal to be generated
without the entry of a valid code into the system when a ward is
operated after an alarm.
Strobe
Confirm
No
If ‘YES’: A ‘STROBE ANY’ output will be activated for 5 seconds
as the system arms. Use with care, in view of potential security
risk.
Re-Arm Omits No
If ‘YES’: At rearm at the end of the confirmation time, this
function will force an input (not a system tamper) causing an
unconfirmed alarm to be omitted, whether it’s still in fault or not.
Use Level
Set*
No
If ‘YES’: The system becomes a ‘level set’ (Having one area set
only at any one time, e.g. part sets). If ‘NO’: The system
becomes a ‘area’ system (setting more than once area at a time)
Confirmed
When
Final
Set
Final Set: Confirmed signal only available after the system is
set. Exit Starts: Confirmed signal available after the exit time
has started. NOTE: Not compliant with DD243.
Note: ‘Exit Starts’ must be selected in order for it to be entered in
the logs.
AutoSet
Force*
No
If ‘YES’ when autoset is in use (this is only available in the plus
software) the panel will still set even if an input is open at the
time.
Restrict PIN
Use
No
If ‘YES’ the system prevents a pin code being entered on the
Entry Time, but allows the system to be silenced once in alarm.
Enable when DD243 option 6.4.5 is in use.
Simple Set No
Enables the ‘simple set’ functionality which allows a user to set
the system by pressing the ‘YES’ key and the level set.
PLEASE NOTE THIS FEATURE IS NOT UK COMPLIANT
Invert ATE
O/Ps
Yes If YES’: ‘Positive Removed’ If ‘NO’: ‘Positive Applied’
Common
Lobby*
Yes
If set to ‘YES’, this will automatically select the ‘highest’ exit
mode for all partitions. (0 = Timed, 1 = Final Door, 2 =
Timed/Final Door, 3 = PTS). For example, if Area C is selected as
Final Door and the rest of the partitions are selected as Timed,
then because Final Door is ‘higher’ than Timed (Final door is 1
and Timed is 0), all partitions will be set to Final Door. If set to
NO’ the Exit Modes will be individually programmable to each
area.
Seitenansicht 41
1 2 ... 37 38 39 40 41 42 43 44 45 46 47 ... 67 68

Kommentare zu diesen Handbüchern

Keine Kommentare