Programming Manual EURO
RINS1291-3 Page: 43
Flexi Unset No
If set to ‘YES’, this will allow all codes with Flexi-Set attribute
enabled to pick and choose which partitions to set/unset during
entry time. This option should always be selected when DD243
option 6.4.5 is in use
2 Key HU None
2 Key Hold Up Alarm at the keypad. The and keys,
pressed simultaneously to produce a hold up.
None: Inactive. Silent: Silent Hold Up. Bells Only: Bells Only
(No signalling). Both: (Signalling and Bells)
EURO keypads do not comply with ACPO requirements for this
facility to be used for police all purposes.
ATE Inputs None
Permits selection of inputs to ATE pins to suit ‘ATE’ (including Red
Care Reset), ‘DigiCom’ (including Telback), ‘Relay Interface
Monitoring’ or ‘Not Used’. Note: This option must be set to ‘ATE’
or ‘Digi’ in order for Line Fault, etc. monitoring to function. This
option is NOT required for use with the digi-modem.
Tag Opens
Doors
No
Used in conjunction with “Entry Control” in Assign
Keypads/Readers (Page:21). If set to ‘No’ – any reader assigned
for ‘entry control’ will arm/disarm as normal, and any doors on
the system are open when the system is unset. If set ‘Yes’ the
readers control the arming/disarming and doors.
*These options are not available on the EURO 28
Site Options
Using the and keys, scroll to ‘SITE
OPTIONS’. Press the key
Set With Fault
Enter : for No. Enter : for Yes.
Press the key. Repeat for all other
options until:
2 Key HU
Enter : for Silent.
Enter : for Sirens Only
Enter : for Both.
Enter : for None Press the key.
ATE Inputs
Enter : for ATE. Enter : for Digi
Enter : for Relay Enter : for None
Press  for the Engineer Menu.