12. TEST AND DIAGNOSTIC FACILITIES
AUTOMATIC TESTS
BATTERY TEST
The system performs a check of
the battery operation every 10
seconds, by dipping the power
supply voltage momentarily, and
measuring the system voltage. If
the battery voltage measured is
below 12·0v, or the battery fuse
has failed, a BATTERY FAULT
warning will be generated.
BATTERY LOAD TEST
Euro-MERiDIAN systems may be
set up to perform an automatic
Battery Load Test at every
power supply at 7:00 am each
day. This will drop the power
supply voltage below battery
voltage, and (G3+ and above)
switch a dummy resistive load
onto the system whilst
monitoring the system
diagnostics.
This test will NOT take place if:
the End Station Siren and
Strobe outputs are live
the system is in engineer
mode
any battery fault exists
any mains fault exists
the site option is not
selected
If the test has already started, it
will be aborted if any of these
conditions apply, other than
entry into Engineer menu.
If the test is aborted, it will NOT
be performed until the next day.
This is selected in SITE OPTIONS.
The test may also be performed
as required, under engineer
control.
OTHER TEST FACILTIES
ENGINEER SYSTEM SET
This permits the engineer code
to set and unset the system.
With display showing
Euro-MERiDIAN
Time 13:45
Enter Engineer code (default
1111)
SET/UNSET SYSTEM?
Press YES
Set Areas
[ABCD]
Select security pattern to be
set, noting that the ABCD keys
will illuminate to reflect the
selection.
Press YES
Setting [30]
A
The system will commence
setting, in
Timed
mode. Exit
time will count down, and
system set.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 46 Software
ENGINEER FORCE SET
This permits the engineer code
to set and unset the system,
forcing it to set despite zones in
fault condition, and nominate
which zone must be triggered to
generate an alarm condition.
With display showing
Euro-MERiDIAN
Time 13:45
Enter Engineer code
SET/UNSET SYSTEM?
Press NO
FORCE ARM ON 1st
ZONE [01]
Nominate number of zone to
generate alarm once set, eg
Press
05
and YES
FORCE ARM ON 2nd
ZONE [01]
Nominate number of
additional zone to generate
alarm once set, eg Press
13
and YES
Set Areas
[ABCD]
etc.
The system will QUICK
-
SET.
Note: In both cases, the system will
give correct ATS response to the
setting, and any resulting alarm
(including sequential confirmation
if
the zones selected provide a valid
combination
). On unsetting, the
system will revert to normal mode.
Note: If the system has been set by
any other code, the Engineer code
will NOT unset it.
KEYPAD DISPLAY TEST
Each Keypad display may be
tested individually. Press B for 5
seconds. All LEDs will light, and
the LCD will scroll the display to
test every pixel, reverting to the
normal display after 10 seconds.
ENGINEER TEST FACILITIES
Walk Test
Permits the detectors on the system
to be tested, for the entire system or
for selected area(s).
The display scrolls through all
programmed zones. As test is
conducted, system chimes, and zone
tested is removed from scrolling
display, until the last zone has been
triggered, or the test aborted.
Note: Exit from Engineer menu to
‘set’ programming before walk
test.
Soak Control
Any zone (except 'FX' types) may be
placed on 'soak test' to prevent it
from generating an alarm. Should it
trigger whilst the area to which is
allocated is set, the system will log
and indicate activation (at unset).
An option is also available to force
the system into 'Engineer Reset'
mode in the event of an activation.
Batt Load Test
Power supply voltage is reduced,
placing system and simulated alarm
load on battery.
Outputs Tests
Sirens (and strobes) can be tested
direct from menu.
Other output types can be selected
(NOT by individual output) using the
output type numbers - see page 44
ALL outputs programmed to that
configuration (inc. slot
-
in DigiModem
and plug
-
on ATE) will be tested.