Started Manual Castle Care-Tech Ltd
5·00 Page 21
9. POWERING UP and ADDRESSING
the KEYPADS
Pre Power-Up Checks
Prior to powering up the system,
a final check should be made of:
1. POWER SUPPLIES adequate
for the load to be applied.
2. WIRING conforms to
specifications in this manual.
3. CONNECTIONS correctly
made, with no loose
whiskers, etc.
When you are satisfied that all is
correct:
Powering Up
Power up the End Station on
MAINS ONLY.
Go to the first keypad, which will
be showing
ADDRESS
[- -]
Key
00
and
A
Euro-MERiDIAN
Time: 00:03
The system will be generating a
tamper alarm, use default code
(1234) to silence. When
Battery Fault is indicated (NOT
BEFORE), the back-up battery
should be connected.
If you have more than one
keypad on the system, they must
all be addressed in the same way,
ensuring that no address
duplicates another Keypad, Tag
Reader or Access Control Point.
When this has been done, any
additional power supplies may
be powered up noting the
same need to await a Battery
Fault indication before
connecting the back-up battery.
NOTES:
A blank keypad display may mean
that it has previously been coded to
an address other than 00 (eg for test
purposes). Press the D key for 10
seconds to access the menu to
enter the correct address as above.
When prompted to enter a code,
this is ‘2000.’
Additional keypads, and any tag
readers on the system will NOT
work unless they are correctly
addressed, AND enabled in the
engineer menu, as shown on page
37.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 22 Software
10. GENERAL PROGRAMMING PRINCIPLES
The various functions are
selected and manipulated as
follows. For simplicity, where
menu content and data entry are
straightforward and obvious, no
detail will be provided in this
basic manual.
ENTERING ENGINEER MENU
On a new system, only Keypad
00 is enabled by default
, and it
is therefore necessary to use this
keypad until the remainder are
enabled from the Engineer
Programming Menu.
NOTE: The system MUST be fully
unset before the Engineer or
Manager menus can be accessed.
Euro-MERiDIAN
Time: 17:24
Enter engineer code
(default 1111)
SET/UNSET SYSTEM?
Press NO
FORCE ARM ON 1st
ZONE?
Press NO
A tamper alarm is
generated
Enter Code
[ ]
Enter engineer code again
Alarm silences
INHIBIT FIRE/HU?
The system is now in the
Engineer Main menu. This gives
access to a number of sub
menus, each of which enables a
system function, or group of
associated functions, to be
programmed.
Main menu items are
distinguished by using CAPITALS.
EXIT
FROM
ENGINEER MENU
On completion of programming
or use of test/diagnostic
functions, the system can be
returned to normal mode by:
EXIT ENGINEER
MENU?
Press YES or
A
Please Wait
Saving NVM data
Please Wait
Checking System
Euro-MERiDIAN
Time: 17:24
OR:
With the display showing any
MAIN menu item (ie shown in
CAPITALS), press A. The sequence
followed will then be as above.