Started Manual Castle Care-Tech Ltd
Page 33 Software
ASSIGNING KEYPADS and
TAG READERS
Ensure that all Keypads and Tag
Readers are correctly addressed
BEFORE enabling them in this
menu.
Each Keypad / Tag Reader can be
assigned to SET and/or UNSET
specified security patterns,
EXCEPT for a G3+ used in LEVEL
setting mode.
In the case of area setting
systems, it is necessary also to
select the Area(s) IN – i.e. the
area(s) in which the set point is
located, to determine which exit
route and mode applies when it
is used to set the system.
See separate instructions for
using Tag Readers as Ward
Controllers, and for setting up
Access Control Points.
TMZ MODULES:
These are addressed and
programmed as Tag Readers.
AREA SETTING SYSTEMS:
Note that the areas that the TMZ unit
is programmed to be “IN” controls
the areas for which the loudspeaker
output will generate tones – thus an
‘area sounder’ output is possible.
ASSIGN KEYPADS/
READERS?
Press YES
Address
[0]
Use number keys (or
D
) to
select address
Press YES
Type
Keypad [0]
Use
D
to select Keypad [0] or
Reader [1].
Press YES
Default Level?
Set Point Sets Areas?
Select the system level /
areas that will be set when
code/tag is used at this point.
Set Point Name?
Permits location identification to
be programmed for Set Point.
Press YES
Set Point Name
Reader 0
Enter text, as described on
page 25.
Press YES
Address
[0]
Key in address of next
Keypad to be programmed,
or NO to exit.
OR
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 34 Software
CHANGING SYSTEM
DISPLAYS
The display information referred
to on page 25 may be tailored to
suit the installation:
With the display showing
SYSTEM DISPLAYS?
Press YES
Area A Text
Area A
Enter text, as described on
page 28 and press YES
Repeat for each text string
Display When Set?
No [0]
Selects whether system
status information (ie
which areas are set) is
displayed, and alarm
events, whilst system is
set.
Permitted only Grade 1&2
systems using a means of
unsetting that does not use
an entry route.
Use
D
to select as required
and press YES
Repeat for each option
SYSTEM DISPLAYS
Press NO to move to next
menu
CHANGING TIMERS
The various timers on the system
are:
Timer
Function
Range
Default
Entry
Time
Entry time for
each Level or
Area
0
–
255
secs
30
Exit
Time
Exit time for
each Level or
Area
5
–
255
secs
30
Siren
Time
Cut off time for
external
sounder
2
–
99
mins
15
0-99
mins
30 Con-
firm
Time
Sets time
period during
which a second
activation must
occur to qualify
as 'sequentially
confirmed'
alarm.
Note: DD243
specifies
between
30 and 60
minutes.
Siren
Delay
Delay after
intruder alarm
before siren live
0
–
20
mins
00
NOT valid within three minutes of final
set, or if entry time started.
Strobe
Time
Time Strobe
output stays
live after end of
Siren time
0
–
99
mins
00
‘
99’ represents endless
Re
-
Arm
Num
ber
Number of
times system
re
-
arms after
end of
Confirmation
time
0
–
9
3
Note: rearm number applies to each
Level or Area, and does not affect
emergency alarms.
’9’ represents always rearm