Started Manual Castle Care-Tech Ltd
5·00 Page 41
Type Default Active Restore
0022 Final Set ANY
-
When FIRST area is set At code entry to unset LAST
area
0036 Shunt Fault
-
For use with shunt input – see Technical Note
Use of
Wards and Shunts.
Output type 0035/0036 cannot be fired by ATE pins.
0037 Reset 1
(Viper Reset)
-
At code entry to set After 3 seconds
0038
-
At code entry to set When unset
Reset 2
(Viper
Set/Unset)
Re
-
triggers whenever an additional area is set.
0039 PIR Latch 1 When set (and in Walk
Test)
On alarm, or when unset
NOTE: restores and re-applied at 'Reinstatement' after unconfirmed alarm.
0040 PIR Latch 2
-
This is the inverse polarity to PIR Latch 1
0052
Mains Fail
ES 4
After pre-set time without
mains power
On restore of mains
0055
Global Fault 1
G2
ATE9
During any fault if the
system is set.
At code to unset AND if fault
clear
0056
Global Fault 2
G3
ATE9
During any fault at any
time
At code to silence AND if fault
clear
0060 Reset Digi ATE 8 At power up Live for 5 seconds only.
0064 Test ATS ATE 10 When output switched in
engineer menu
When test completed
0066 ATE Not Used ATE 8
ATE 9
Constant +5v, does not switch or restore
This configuration MUST always be programmed to STU output 8 if a
plug-on DIGICOM is in use (not required for STU).
Principal types from the above list are also available on a 'per Area' basis - see full Engineering
Manual.
The following types are available for all systems (see also type 035 for G3+ and MSX panels).
1001 Follow
zone 1
-
When input 1 is
activated
When zone clears
to
1256 Follow
zone 256
-
When input 256 is
activated
When zone clears
ie add 1000 to the input number to select the output type required.
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 42 Software
SEQUENTIALLY CONFIRMED OUTPUTS
The first detector to alarm will cause
an
intruder
signal to be sent to the
ARC, as an
UNCONFIRMED
alarm. If a
second detector goes into alarm
prior to the end of
confirm' time,
the
CONFIRMED
signal will be sent
to ARC for notification to the police.
A repeat trigger of the first detector
will be ignored.
Two inputs within the same "Confirm
Group" cannot provide confirmation
(see page 31).
If the
CONFIRMED
signal has NOT
been sent by the end of confirm
time, the system will reset and
(subject to setting of ‘rearm count’)
rearm. The ‘intruder’ signal WILL
restore. In the event of a further
trigger before the system is unset,
the full cycle of alarm events is
available, as above.
For additional information,
including operation on entry
route and other special
features, see full
Engineering
Manual.
AREA SOUNDER OUTPUTS
There are no programmable
area
sounder
configurations available.
However, the third output on a TMZ
module is configured as a
loudspeaker driver, and suitable
programming of the options for the
TMZ provides area sounder outputs
(see page 33).
PROGRAMMING STEPS:
With the display showing
CHANGE OUTPUTS?
Press YES
End Station
Outputs?
Press NO to move to next set
of outputs, or Press YES
Output 1 [014]
Siren Any
Use number keys to select
output type from table on
page 44, or
D
or
B
to scroll
through available options
Press YES
Output 2 [016]
Strobe Any
Repeat for Outputs 2, 3 and 4
Press YES
ATE OP 1
Fire [001]
Repeat for ATE OP 1 to 9
Press YES
End Station
Outputs?
Etc. to
CHANGE OUTPUTS?
Press NO
Moves to next menu item
NOTE: In some cases there will be
a delay of up to 10 seconds before
the display updates after selecting
an output type that ‘jumps’ an
unused type number.