Started Manual Castle Care-Tech Ltd
5·00 Page 43
INTELLIGENT SETTING
LEVEL SETTING SYSTEMS
Setting the system in pattern
A
will commence
intelligent setting
of the whole system, with the exit
tone at
intelligent
volume level.
Activating the nominated zone
during exit time will cause the
system to switch to & set pattern
B.
AREA SETTING SYSTEMS
Setting the system with any code
including area B will initiate setting
the areas for which the code/tag is
valid, with the exit tone at
intelligent
level.
Activating the nominated zone
during exit time will cause the
system to OMIT area B, and
quick
-
set
the remaining areas.
In order to unset successfully, it is
essential that a detector be sited to
start entry time before entering the
code. If this is not done, additional
areas will set, instead of unsetting.
ALL SYSTEMS
If an FX zone is triggered before the
nominated zone, the system will
switch to full setting (or as
determined by code validity) and
continue to set, using normal exit
mode.
NOTES:
It is NOT possible to ‘Intelligent set’
other combinations of security
patterns.
If 'intelligent set' is in use, the exit
route must be designed so that an
‘FX’ detector can only be triggered
when the system is definitely
required to ‘fully’ set.
The 'intelligent' detector must be
sited to ensure that ALL potential
system users are correctly detected.
Some 'pet-immune' detectors are not
suitable.
Do NOT use a door contact as the
‘intelligent’ zone.
Programming Steps
With the display showing
INTELLIGENT SET?
Press YES
Intelligent
No [0]
Use
D
to choose No [0] or Yes
[1]
Press YES
Intelligent [--]
Insert input number required
to switch to
Part
set and
press ‘Yes’. To remove an
input from the list, key in the
zone number again,
Press YES
INTELLIGENT SET?
Press NO
Moves to next menu item
Castle Care-Tech Ltd Euro-MERiDIAN Getting
Page 44 Software
SITE OPTIONS
A range of options is available to
tailor the operation of the system.
See full Engineering Manual for
details. Please note especially:
Rearm
Isolates
Forces the zone triggering an
'unconfirmed' alarm to be
isolated at rearm (re-
instatement) at the end of
'confirm' time, whether the
zone be in fault or not.
Use
Level set
Permits
Euro
-
44+ to be
selected to function in
Level
setting
mode.
See
page 34.
ATE
Reply
Permits selection of inputs on
plug
-
on
or loom connector
to suit
STU
(inc. Red Care
Reset),
Digicom
(inc. Fail to
Communicate),
Relay
Interface monitoring
or
not
used.
NOTE
: This option MUST be set to
'STU' or 'Digi' in order for Line
Fault (and other) Monitoring to
function.
Invert
ATE O/Ps
Changes outputs at ATE pins
(on End station only), to
trigger as “POSITIVE APPLIED”
instead of the default
“Positive Removed.”
Common
Lobby
If selected as ‘YES’ (default),
system will automatically
select the highest priority
exit mode from all the areas
that are capable of being set
from that set point.
If selected as ‘NO’, system will
select the highest priority
exit mode from these areas
actually being set at the time.
Restrict
PIN
Codes
If set to ‘YES’ then PIN codes
can still be programmed but
will not work during entry
time.
ENGINEER RESTORES
Engineer Resets may be performed by:
Use of Engineer code on site
Use of
remote restore anticode
(if
option enabled) to generate a
reset code from a PC
programme that will perform
the Reset
Red Care Reset from Alarm
Receiving Centre
Download Reset from PC running
Euro
-
InSite
software
If Engineer Restores are programmed, an
engineer must reset the system before it
can be used again. This will not interfere
with the generation of an emergency
alarm.
Options are available as follows:
Engineer Restore of HU
Following a Hold Up (HU Device or
Duress) alarm.
Engineer Restore of Intruder
Following an intruder alarm. This may
be selected to operate either on
generation of standard
Intruder
signal, or
Secure Intruder
signal.
Engineer Restore of Tamper
Following a Tamper alarm.
Engineer Restore of Soak
In the event of a zone with the
soak
attribute triggering whilst the system
is set.
Engineer Restore of Confirm
Following an sequentially confirmed
alarm.
Anticode restore
Enables system to display an anticode
whilst awaiting Engineer Reset, which
can be used to generate a special
reset code.