SPECIFICATIONS
This chapter outlines the essential specifications for the Euro-
MERiDIAN range.
Castle Care-Tech Ltd. reserve the right to change these specifications at
any time, without notice, in the interests of product improvement.
Please ensure that this
information is used in designing
the system, so that it can be
installed and programmed as
intended, and will continue to
function reliably. In particular,
system outputs and power
supplies must be used within
their rated specifications.
A: EN-50131
System components (including
the expansion products) are
suitable for use in systems
specified as follows:
Product Security
Grade
Environment
Class
Euro-10 1 and 2 1 and 2
Euro-12 1 and 2 1 and 2
Euro
-
22 1 and 2 1 and 2
Euro
-
28 1 and 2 1 and 2
Euro
-
44+ 1 to 3 1 and 2
Euro
-
134 * 1 to 3 1 and 2
Euro
-
256 * 1 to 3 1 and 2
External
Tag Reader
Head
-
1 to 4
(IP65)
*-
Euro
-
134 and 256 are simply Euro
-
44+
fitted with MSX Card.
B: SYSTEM SPECIFICATIONS
Euro
-
10/12 22/28 44+ 134 256
Power
Supply
1.2 or
1½A
1½A - - 1½ or 2½A - -
Zones
(max)
10 / 12 22 / 28 44 134 256
Set points
(max)
4481630
of which,
max
keypads:
448916
Level
(Part) Sets
44 4
-
-
Full Areas
--
Option:
48 14
Wards
(max)
3371516
User/
Manager
Codes
†
12 20 100 230 500
Duress/
Guard
Codes
†
10 10 20 20 20
Logs
400 400 750 2000 3000
Access
Control
(max)
NO NO 7 15 16
Output
Modules
11288
†
-
Plus Engineer and Master Manager Codes