Castle Care-Tech Ltd. Engineering
Page 13 - 18 Chapter 13
Timer Function Range Default
Speaker
Time
Time Speaker and Keypad Bleeper
outputs remains live after Siren
Time ends
0
–
99
minutes
00
‘99’ represents endless
Settle
Time permitted after exit
procedure is complete before
system active (to permit exit route
detectors to settle).
0
–
255
seconds
05
Double
Knock
Length of filter period applied to
zones with
‘
double knock
’
attribute
0
–
75
seconds
10
Pre
-
Alarm
Delays
‘
intruder
’
output signal if
entry time has started
0
–
99
seconds
30
SEE NOTE ON PAGE 9-4.
Line Fault
Duration of Telecom Line Fault
before
‘
Line Fault
’
alarm triggered
0
–
99
seconds
20
‘250’ represents endless
Set Fail
Time after which
‘
Set Fail
’
operation will be invoked if exit
procedure not completed
0
–
99
seconds
40
Guard
Code
Alarm
Minimum time an alarm must have
existed before a
‘
Guard code
’
will
be accepted to unset.
0
–
10
minutes
03
Fire Siren
Time
Cut off time for Fire alarm 0
–
99
minutes
00
‘99’ represents endless
NOTE: 'Entry,' 'Exit' and 'Siren' timers are individually programmable
for each area / level.
PROGRAMMING PROCEDURE:
With the display showing
CHANGE TIMERS?
Press YES
A Entry Time
[030]
Adjust time as required, with
numeric keys
Press YES
A Exit Time
[030]
Repeat for each timer . . .
Press NO
CHANGE TIMERS?
Press NO
Moves to next menu item