Page A1
You’ve Made the Right
Choice
Contents
Introduction A1-4
Using Euro-MERiDIAN with Code
or Tag
B1-5
Intelligent Setting B6-7
When Problems Arise C1-2
Setting Individual Area D1-3
Chime Facility E1
Omitting Zones E2-3
Keypad Personal Attack E4
Manager Menu F1-2
Omitting 24 hr Zones F3
Changing Date & Time F4
Change/Add Codes or Tags F5-10
Review History Log F11-12
Walk Testing Detectors F13
Testing your Sounder F14
SMS Messaging System F15-16
Manager Menu Exit F17
Service & Codeholder Records G1-2
Note the specification of Euro-MERiDIAN may vary
between models, and some facilities in the manual
may not be available. Check with your installer for full
details.
© Castle Care-Tech 2004
Seitenansicht 0
1 2 3 4 5 6 ... 47 48

Inhaltsverzeichnis

Seite 1 - You’ve Made the Right

Page A1 You’ve Made the Right Choice Contents Introduction A1-4 Using Euro-MERiDIAN with Code or Tag B1-5 Intelligent Setting B6-7 When Problems

Seite 2

Page B4 Faults when Leaving the Building If when you have closed the final exit door (and pushed the ‘Push to Set’ button if fitted), the exit ton

Seite 3 - The MERiDIAN Keypad

Page B5 Entering the Building Power Alarm Tamper Fault Unset To enter the building you must use the agreed entry route and go straight to the keyp

Seite 4 - Warning Indications

Page B6 Part-Setting the System Intelligent Set If you wish to set Euro-MERiDIAN and stay in the building (eg set the alarm at night), the Euro-M

Seite 5 - Using Tags

Page B7 Staying in the Building Intelligent Set To Part Set Euro-MERiDIAN go to the keypad and enter your PIN code or present your Tag. The appr

Seite 6

When Problems Arise, Just Key in your PIN Code or

Seite 7 - Security Checks

Page C1 Silencing Alarms Power Alarm Tamper Fault Unset If an Alarm tone sounds: Just key in your PIN code or Present your Tag. The Alarm will s

Seite 8 - Leaving the Building

Page C2 Engineer Reset When an alarm has been cancelled a random 5-digit code may be displayed, along with the message: “RESET REQUIRED” Normally

Seite 9 - Faults when you Switch On

This Page has been left Blank for Notes

Seite 10 - Building

Setting Individual Areas

Seite 11 - Entering the Building

Page D1 The A B C D Keys Sometimes your security needs will be a little more complex and you will need to use the A B C D keys. Your Installer c

Seite 12 - Part-Setting the System

Page A2 You’ve Made the Right Choice Using your Euro-MERiDIAN Alarm System just couldn’t be easier!

Seite 13 - Staying in the Building

Page D2 Codes with Flexi-Set For greater flexibility in setting parts of your system, you can make a choice at the keypad. Key in your PIN code o

Seite 14 - Key in your

Page D3 Flexi-Set When Euro-MERiDIAN is already set and you wish to unset: Key in your PIN code or present your Tag. If entry timer has started:

Seite 15 - Silencing Alarms

More Advanced Functions

Seite 16 - Engineer Reset

Page E1 The ‘Chime’ Facility The ‘C’ key can be used to select the ‘chime’ facility while the system is Unset. For example, you may wish to b

Seite 17 - Blank for Notes

Page E2 Ignoring an open door or Window In a domestic setting you may wish to ignore a window you have deliberately left open in the summer time.

Seite 18 - Individual

Page E3 Deliberately omitting a zone when leaving the building At some time you may wish to isolate a detector if a room is occupied. Enter you

Seite 19 - The A B C D Keys

Page E4 Keypad Personal Attack If you ever need to summon personal assistance in an emergency, Euro-MERiDIAN allows you to do so. Simply press t

Seite 20 - Codes with Flexi-Set

This Page has been left Blank for Notes

Seite 21 - Flexi-Set

Page E4 Keypad Personal Attack Manager Menu To enter Manager Menu, simply key in your Manager Code. Your system must be fully disarmed to ente

Seite 22

Page F1 Manager Menu The manager menu is accessed by keying in your Manager PIN code. You then have a choice of: Set System? Set Date & Ti

Seite 23 - The ‘Chime’ Facility

Page A3 The MERiDIAN Keypad The display gives you any important messages. It will alert you if you need to call your alarm installation engineer.

Seite 24 - Ignoring an open door or

Page F2 Manager Menu Power Alarm Tamper Fault Unset With the system Unset Key in your Manager PIN code. The ‘Unset’ lamp will light. The firs

Seite 25 - Deliberately omitting a

Page F3 Omit Zones Press ‘YES’ (Press ‘NO’ to move to the next Menu) Some of your doors may rarely be used. Opening them, even with Euro-MERiDIA

Seite 26 - Keypad Personal Attack

Page F4 Changing Date & Time Press ‘NO’ to move to next menu. Press ‘YES’ (Press ‘NO’ to move to the next menu) Enter Year (eg 01=2001) Pr

Seite 27

Page F5 Changing or adding PIN Codes/Tags A record should be kept as shown on Page G2 Press ‘YES’ (Press ‘NO’ to move to the next Menu) Press ‘

Seite 28 - Manager

Page F6 Changing or adding new PIN codes/TAGS Euro-MERiDIAN identifies each user by a different ‘User Number’. Eg ‘John’ would be user 01 – ‘Jane’

Seite 29 - Manager Menu

Page F7 Changing or adding PIN Codes/Tags Choose the level of authority the code-holder is allowed. User – cannot access Manager Menu. Manager –

Seite 30

Page F8 Changing or adding new PIN codes/TAGS Flexi-Set gives you the opportunity to choose the areas you require to set when you use your PIN co

Seite 31 - Omit Zones

Page F9 Changing or adding PIN Codes/Tags If you do not have Access Control or Wards, go to page F10. Press ‘YES’ (Press ‘NO’ to move to next me

Seite 32 - Changing Date & Time

Page F10 Changing or adding new PIN Codes/Tags Using the numeric keys, you can enter a user name, similar to typing a text message on a mobile pho

Seite 33 - PIN Codes/Tags

Page F11 Review History Log Press ‘YES’ (Press ‘NO’ to move to the next menu) Press ‘YES’ To advance through the logs: Press ‘D’ For added in

Seite 34

Page A4 Warning Indications Power Alarm Tamper Fault Unset Power Alarm Tamper Fault Unset Power Alarm Tamper Fault Unset Power Alarm Tamper Fault

Seite 35

Page F12 Review History Log If Access Control Facility is in use, a separate log is available dedicated to events using this function. Follow the

Seite 36

Page F13 Check all detectors are working Press ‘YES’ (Press ‘NO’ to move to the next Menu) Choose the area(s) you wish to test by pressing the a

Seite 37

Page F14 Testing your Alarm Sounders Press ‘YES’ (Press ‘NO’ to move to the next menu) Press ‘YES’ Siren will sound, Strobe will flash Press

Seite 38

Page F15 SMS Messaging System Your system may have been configured to send messages to a mobile telephone. If so, the system will call the approp

Seite 39 - Review History Log

Page F16 SMS Messaging System It is recommended that this test is only undertaken under the supervision of your alarm installation engineer. Pres

Seite 40

Page F17 Menu Exit This menu is reserved for your Service Engineer and cannot be accessed by normal users. Press ‘NO’ to move to next menu. To e

Seite 41 - Check all detectors are

Page G1 Service Information We are sure that you will be delighted with your Euro-MERiDIAN Alarm installation. For your personal reference here i

Seite 42 - Sounders

Page G2 User Codes Warning: This information should be removed from the manual and stored in a secure location. Photocopy this page if you have m

Seite 43 - SMS Messaging System

Page G3 Disclaimer Euro-MERiDIAN includes the facility to send electronic signals to an AlarmReceiving Centre (ARC), and also to send SMS text me

Seite 44

Page A5 Using Tags Euro-MERiDIAN’s High Security Proximity Tag (or Card) will set or unset your Alarm system with the minimum of fuss or complexi

Seite 45 - Menu Exit

Using the Keypad with your PIN Code or

Seite 46 - Service Information

Page B1 Security Checks Before you activate your system: You must ensure all doors and windows are securely closed and any pets or people are excl

Seite 47 - User Codes

Page B2 Leaving the Building If you are leaving the building, go to Keypad and key in your PIN code, or present your Tag. Exit tone Starts The

Seite 48 - Disclaimer

Page B3 Faults when you Switch On Power Alarm Tamper Fault Unset If when you key in your PIN code (or present your Tag) a warning tone sounds and