Manual Euro-MERiDIAN
Chapter 16 Page 16 - 7
Programming the
Outputs
With the display showing
CHANGE OUTPUTS?
Press YES
End Station
Outputs?
Press NO to move to
appropriate set of outputs, eg
Output module, and select
output number required:
Press YES
Output 3 [00]
Not Used
Select as FOLLOW ZONE output
type 10xx where xx is the
number of the programmed
Shunt zone, eg 1018 for zone
18.
On Euro
-
134 and 256, type 035
may alternatively be used, as
follows:
Output 4 [035]
Follow Zone
Press YES
Follow Type
Follow [0]
Press YES
(ignore alternative settings)
Follow What?
Zone [0]
Use
D
to select
Shunt List [1]
Press YES
Follow When?
When Set [0]
Use
D
to select
Always [2]
Press YES
Shunt to Follow
[001]
Enter the number of the zone
controlling the shunt list.
Press YES
The
Follow Zone
output is
now programmed.
FOR ALL SYSTEMS:
To programme the
shunt fault
output:
Output 4 [000]
Not Used
Select output type 026
Output 4 [026]
Shunt Fault
Press YES
Select Shunt
zone [01]
Select number of Shunt zone,
eg 18 (or 018) and press YES
This step is not required on Euro-
22 and 28.
Repeat for additional shunts, or
press NO to
CHANGE OUTPUTS?
Press NO
Moves to next item